Product
From search to signed report, step by step.
A snapshot covers one device and one period. It collects the evidence, helps people decide what matters, and keeps a record of every search, decision and approval along the way. Here is each step in detail, then what runs between reports and around them.
The eight steps of a snapshot
- 01
Collect
Literature, FDA adverse events and recalls, Health Canada recalls and incident reports, and European field safety notices for one device and period. Every query is logged.
- 02
Screen
Rules exclude only the obvious. People decide the rest, with reason codes. AI screening is optional.
- 03
Signals
Complaint trends, rising FDA device problems and field safety notices, ranked for investigation.
- 04
Appraise
Each included paper is graded for suitability and contribution, and weighted.
- 05
Risk file
Evidence is linked to the hazards in your ISO 14971 risk file. Rates above the estimate and possible new hazards are flagged.
- 06
PSUR
PSURs for the EU, GB and Health Canada, and the documents around them, regenerated from the evidence next to your narrative.
- 07
Sign-off
Submitted, reviewed, and signed by a second person who confirms with a one-time code.
- 08
Report
HTML, PDF and Word, rebuilt from the same data. The signed files are kept as approved.
01 · Collect
Every source, searched and logged.
PubMed and Europe PMC for the literature, openFDA for adverse events (MAUDE) and recalls, Health Canada for recalls and incident reports, and field safety notices from the MHRA, BfArM, ANSM, Swissmedic and AEMPS. Exactly what was asked of each source, and what came back, goes into the audit trail and an appendix of the report.
Field safety notices
- MHRA: every weekly field safety notices page, plus device safety information alerts.
- BfArM: notices whose title doesn’t name a search term are marked as document-text matches, listed for review but not signals on their own.
- ANSM and AEMPS: titles are in French and Spanish, so they match on brand, manufacturer and the device’s local names.
- Swissmedic: each product in a notice is judged on its own name and device class.
- Health Canada: recalls match on the product name in their title; incident reports match on trade names and the device’s preferred name, with IMDRF codes.
- Terms match whole words in any language, accented letters included, with an optional plural.
A source that doesn’t answer is retried for up to 24 hours while the rest of the snapshot is ready to work on. Errors that won’t fix themselves are recorded as failures, not retried.
Volumetric infusion pump (sample), 13 Oct 2026. Queries shortened.
02 · Screen
People decide. Rules and AI only take what they can justify.
Rules exclude only what is obviously out of scope: non-human studies, editorials, other device types you list. 10% of those exclusions are sent back to a person as a quality check. Everything else waits for a person.
Optional AI screening
- Off by default. Choose an Ollama model, which can run on your own server so nothing is sent to an AI company, or Anthropic’s Claude.
- It decides only confident, consistent cases (confidence 0.8 by default). Uncertain records and 10% of its exclusions go to a person.
- Claims that can be checked are checked: an “outside the period” exclusion for an in-period paper goes to a person.
- Every AI decision records the provider and model, and people’s later decisions always win.
- Before trusting a model, compare it with your own decisions: agreement, records it would send to a person, and relevant records it would have wrongly excluded.
Reason codes, as printed in the report
| I1 | Safety outcome or adverse event |
| I2 | Performance or clinical effectiveness |
| I3 | Usability or use error |
| I4 | State of the art or alternative therapies |
| X1 | Not the device type under surveillance |
| X2 | Non-human study |
| X3 | No safety or performance data (editorial, news) |
| X4 | Duplicate of another record |
| X5 | Outside the surveillance period |
| R0 | Needs a human decision |
03 · Signals
Trends tested, not eyeballed.
Import your complaints, and optionally units sold, as CSV. Complaints need a date and a category; product, seriousness, IMDRF code and country are used when present. Every other column, including free text, is discarded on import.
Your complaint data
- With units sold, rates are per 1,000 units and each month gets a u-chart control limit from the earlier months.
- Each category is tested for a significant rise in the last three months (one-sided Poisson test, p < 0.01).
- Serious incidents are counted but left out of the trend tests, as they are reported individually.
- IMDRF codes are checked and counted by annex and code, with IMDRF’s 2026 term names for device problems and health effects. Retired codes are marked with the year they were retired.
FDA and European data
- Device problems rising in MAUDE are re-counted exactly before they appear as signals.
- FDA recalls and European field safety notices in the period are listed, and matching notices become signals.
Volumetric infusion pump (sample). Complaint data synthetic; adverse events from openFDA.
Synthetic example data, Nov 2025 to Oct 2026
Synthetic example data, Oct 2025 to Oct 2026
Illustrative counts. Term names from IMDRF’s 2026 release.
04 · Appraise
Every included paper, appraised and weighted.
Each included paper gets a study design, suitability for this device (device, application, patient group, report quality, each 1 to 3), contribution (design, outcomes, follow-up, statistics, clinical significance), key and safety findings, and a weight.
- The weight is suggested from the answers and can be changed with a reason.
- The criteria follow the example scheme in MEDDEV 2.7/1 rev 4.
- Appraisals are versioned like decisions, and the report stays a draft until every included paper is appraised.
- Find open-access PDFs from PubMed Central, Europe PMC and Unpaywall, or upload your own as reference material.
05 · Risk file
Evidence linked to your hazards.
Import the hazard list from your ISO 14971 risk management file as CSV. A person links each piece of evidence (FDA problems, complaint categories, notices, papers with safety findings) to a hazard, helped by suggestions from shared words.
- Flags show hazards whose observed complaint rate is above the risk file’s estimate.
- Notable evidence that a person says fits no hazard is flagged as a possible new hazard.
- The result is a section of the report and of the PSUR, and carries forward to reruns.
06 · PSUR
One evidence base, several reports.
The PSUR tab drafts the periodic reports from one set of narratives. Each section shows what the snapshot found, regenerated every time, next to your narrative. Choose one or more outputs, each a Word file signed with the snapshot report.
Outputs
- EU: a PSUR (MDR Article 86) for class IIa, IIb and III, structured following MDCG 2022-21, or a PMS report (Article 85) for class I.
- GB: a PSUR or PMS report under the UK MDR rules in force from 16 June 2025, following the MHRA’s standardised PSUR format.
- Health Canada: the summary report and, when Health Canada asks for one, the issue-related analysis.
- Alongside them: the trend report, PMCF evaluation report and SSCP change summary, each marked ready before the snapshot can be submitted.
- Sales, population, PMCF, corrective actions and the benefit-risk conclusion are entered by hand, and missing ones are listed.
- Deviations from the PMS plan in force show in the methods section.
- Optional AI drafting suggests sections with a citation on every sentence, for a person to accept or edit.
- Due dates are on the regulatory calendar, with reminders.
07 · Sign-off
Reviewed and signed by a second person.
Once the literature is reviewed, every included paper appraised, every document ready and no source is missing, the snapshot can be submitted. Submission locks it: no decisions, appraisals, imports, risk links, PSUR or document edits.
- Reviewers comment, recommend approval, or send it back for changes.
- Someone with permission to approve, who didn’t submit it, ticks the statement they sign and enters a 6-digit code emailed to them (valid 10 minutes, 5 tries, one use).
- Approval checks the content is exactly what was submitted, then stores the signed PDF, Word report, PSURs and documents with SHA-256 fingerprints.
- A revision unlocks the next version and keeps the signed files of earlier ones.
- A snapshot and its signed report can be shared with a notified body through a read-only link.
08 · Report
One report, three formats.
HTML, PDF and an editable Word document, all rebuilt from the same data. The Word file uses built-in heading styles, so the navigation pane and table of contents work, and includes the charts as images.
- The report stays a draft until the work is done, and names any missing source.
- Appendices list every search run and every reason code.
- On a rerun, a “What’s new” section summarises what changed since the previous snapshot.
Between reports
Watching the device between reports.
A snapshot covers a period. These keep watch in between, for the people who can see each device.
Reports and documents
One evidence base, several reports.
The same snapshot feeds the periodic reports, the documents around them, the PMS plan and the clinical evaluation.
Device templates
20 templates to start from.
“New snapshot” can start from a template with FDA product codes, MeSH headings, safety terms, exclusions and the device’s name in French, German, Italian and Spanish. Adjust any of it for your device.
- Volumetric infusion pump
- Insulin pump
- Continuous glucose monitor
- Blood glucose meter
- Pulse oximeter
- Multi-parameter patient monitor
- Total hip replacement
- Total knee replacement
- Central venous catheter
- Urinary catheter
- Surgical stapler
- Implantable pacemaker
- Critical care ventilator
- Advanced wound dressing
- Coronary stent
- Breast implant
- Automated external defibrillator
- Duodenoscope
- Dental implant
- Hernia mesh
Known limits
What it doesn’t do.
An instrument is only useful if you know its range.